Ground wire has become hot, any idea where to start looking? Problem is between the Service Panel and the first receptacle.
Robnoxious SoCal
For a ground wire to get hot, you have to pass a lot of power through it. Unless you get free electricity, fix that fast!
If it is not a plugged in appliance that is causing it, (easy enough to check by unplugging whatever is plugged in there) the first step would be to turn the breaker off and replace the receptacle. The black wire goes to the brass terminals, the white wire goes to the silver terminals, and the ground wire goes to the sixor eight sided green ground terminal.
If that does not cure the problem, then please replace the cable between the breaker box and the receptacle before the house burns down. If you can't fix it today, turn the breaker off until it can be fixed. Also top off your insurance and keep some FULL fire extinguishers handy. The problem you have is not a joking matter, but very serious!
Because the possibility exists that a nail or screw penetrated the cable, don't touch any picture frames or nails or screws in the wall until the problem has been fixed. That could be a very shocking experience.
If you think that cutting the wall open to replace that wire is messy, consider the alternative: a burned down house. That is a LOT messier.
Before cutting the wall open or doing anything with wall board, move your computers as far away as possible and cover them with plastic. Dust from Gypsum, wall-board, sheet-rock, etc. WILL HURT your CD drives.
Next attach a no-slip drop-sheet or piece of old carpet to the wall ABOVE the baseboard with ducktape or masking tape.
With the breaker off, use a small wall board saw or box cutter and cut a slit wide enough to see the cable.
Before pushing in the new cable, push in a single wire or haywire. You can guide it along by reaching into the slit in the wall with needle-nose pliers. Then use that wire to pull in the cable. Don't try it alone. Have one person pushing and one person pulling.
Once the new cable is connected to a new receptacle and everything is working fine, get some cheap hemp or sisal rope the same length as the cable that you bought and about the thickness of the slot in the wall. Cut the rope into foot long pieces, Soak pieces of the rope in thin wall-board mud and stuff them into the slit so that they don't stick out farther than the surface. That rope trick will save you hours and money and frustration.
Let the rope dry overnight and then finish the wall like you would for surface scratches.
Don't uncover or bring back the computer(s) until all the dust has been vacumed up and the wall sealed with paint.
If you can't do it now, turn the breaker off and take it out, so that nobody can turn it on. A hot ground wire means you have an almost burning house.
Good Luck!
DearWebby
webby.com/
half of my circuit is fine... on the other half I have the 120vac from black to ground but only about 7 vac positive to neutral and 0 neutral to ground. just bought this hose and this is one of the few remaining problems Im haveing. any ideas on an easy way to isolate the problem?
Old house, remodeling bathroom. Feed from panel to light in ceiling. From there 2 separate wires spliced at ceiling fixture....1 to wall light and 1 to switch on wall that operates both lights. Is this safe? I changed out the ceiling fixture to a bath fan and connected the wires back.
I recently removed a three way switch with the hopes of replacing with a new one, however everytine I try to hook it up I blow the breaker. Any idea's on what is causing this? The old switch seemed to be wired wrong because it would only work if the other switch was in the correct position.
I have five garage light sockets wired using one switch. When the switch is flipped one light is fully illuminated- the other four are considerably dimmer. This is on a new wiring project. what could be wrong?
For no apparent reason my kitchen outlets stopped working. I also realized my stove wasn't working. I checked all the breakers, but none were tripped. A few minutes later they started working again, except the stove. Now the power to these outlets comes and goes.
Here's where it gets weird, when checking breakers, I shut off the breaker to my stove (220) and it shut off my kitchen lights and power to outlets. I'm no electrician, but I'm pretty sure that shouldn't happen.So my fluorescent light wasn't working. Rather than replace the ballast I just bought a new shop light fixture. However when I hooked it up and placed the bulbs in it doesn't light. What could be my issue?
What do I need to change on a three way switch so that both switches can be used to control the lights? Right now both switches have to be on for the lights to work.
I recently rewired a 3-way switch because it was not working properly. The problem did not resolve itself. Then I accidentally discovered that the 3-way switch in the hall works perfectly, but only when a different breaker is shut off.
Why would this happen?Your switch may not be wired correctly, or may have a broken connection. This article can help:dengarden.com/
When you wire a switch, you only wire with 1 cable. An electric cable normally has 3 cables inside the thick black outer casing.
I installed a light in the bathroom of my condo which is connected on the same line as my bathroom, my other bathroom, and outlets in my bedroom. A two copper wire cover in alum coil was used to connect them and now every so often the light flickers and sometime goes out and then comes back on.
I'm all for do it yourself projects, Morris, but wiring problems can be serious. Please check your home insurance policy and be sure your smoke detectors are fully functional. Maybe think about hiring a professonial to check your work?
I added a switch to an existing light that just had a pull string, and I wired in a new switch and now when I turn the new switch on it turns on and if the other switch is turned on in the other room it turns that light on and off, also. After digging around I found that the power is shared, is it possible to wire the light so that this does not keep happening. Thanks.
Since you added the switch, you no longer have a "hot" to the light, you have a "switch leg" which is only hot when the switch is on.
The other switch was fed from the hot which is now a switch leg. You need to feed it with a hot. This can be done if there is an extra wire between the switch and the light.
An electrician can help you identify a hot circuit to tie your other switch into.
Good Luck.
The switch on the wall operates the outlet. I just put a ceiling fan/light in. Both the outlet and fan are wired with 12/3. I would like to put in 2 switches. I have tried everything I could possible think of. I have been up all night, back and fourth to the box. I was able to get the fan and light to work, but not the outlet.
I was able to get the outlet, but not the fan. So I have a black and white coming in - the switch. I have red white and black coming in - existing . I have new red white and black coming. Please help - I am driving myself crazy! I have tried three way switches-single pole. I will await your help! Thank you in advance.I would talk to an electrician. They have the tools and meters to make sure the job is done safely. Box fill could rapidly become a problem here. Without meters, assumptions have to be made that code was followed (black is hot, white is neutral.....)
I have this sketch on how it should be done to have the fan always powered and the light on the switch.
The wiring in my home is chirping and won't stop. It is not the smoke alarm.
By John from Los Angeles, CA
I would be calling an electrician right away. He/She could most likely tell you why while they are fixing it.
I had cabinets installed in my garage and somewhere the installer hit a 220 line and the line won't reset. The installation company is sending a man using trial and error to find which screw is touching the line. My question is once we find the screw and relocate it is the wire OK or is it a potential fire hazard? If it is a hazard would installing a junction box be OK or do I need to rewire?
By Tim O. from Anaheim, CA
My electrical wiring is making a static noise and there is a burning smell near the junction box and electrical breaker box. What should I check for since I have turned the breaker off?
By Gaspare
You should check for the number of an electrician. If you are smelling a burning smell, you've got a fire somewhere. Be sure your main breaker is shut off. This is not something you should be fixing yourself. Hopefully, your home hasn't caught fire by the time you read this.