My wife's light switch stayed on all the time and my buddy took one out of another room and took the wire in the screw out first and then the one in the hole and then moved it to her room. It worked and then he tried to put the one that stayed on all the time where the other one was. He put in the wire that went in the hole first and he blew a breaker. Should he have put the top one in first then the one that went in the hole in next? Or is it the switch itself that is bad?
By AN from NY
I think that what you have is the blind leading the blind. Some things, like changing light switches, are simple tasks that home handymen can do, but sometimes, when things go wrong, it is time to call in someone who is trained. Toss the old light switch, at the very least, and put in a new one. But I think you need to call in a professional.
Why are my lights on when the switch is in off position and the on breaks the circuit?
I think you switch is incorrectly wired. Call an electrician to get it fixed.
Is the off and on labelled? If not, it could be that the switch was installed upside down. Have an electrician turn the switch over.
Is this part of a three way circuit?
In my bedroom I have one wall light switch that operates a ceiling fan. There are also 3 other outlets in the room. The problem I'm having is my ceiling fan, when on, will suddenly stop working; the lights also.
Sometimes it can take 2 hrs up to a few days before the light switch works.Recently I changed a faulty light switch in one room and right after doing so the light switch in the adjacent room stopped working. I tested the lines for power and it came up negative. Is this something that can be easily fixed or do I need to call an electrician?
I would always recommend an electrician.
Assuming the other switch is for a different light fixture, what may have happened was that in the process of changing your switch the hot wire feeding the other switch came loose under the wire nut.
@Bruce S: thanks so much for the advice! It worked. I was able to fix the light based on your suggestion :)
I have a light pole near my dock with one plug outlet near the top. The switch for that light pole is on the outside wall of my pool deck. On the house that is near my backdoor, there are 2 switches in that box and one is for that pole and the other for the pool lights that change colors.
My friend plugged in a 5 hp compressor into that pole and blew something because now I have no power to the pole or the pool lights. The breakers are not tripped, I re-set them all and still no power, I checked the current and there is no power getting to those 2 switches on my back wall, what could it be now? Thanks so much for any info.
By John2112 from Cape Coral, FL
John, I don't think your friend 'blew something' as much as he/she burned something. This is a job for a professional, someone with the high-end tracking tools to find where the burn-out is. Make sure to contract with someone who is licensed in your area and the state, and check with the Better Business Bureau to make sure you aren't accidentally hiring a shady character.
You might want to shut the power feed off to that area as well to keep the fire hazard down until you can get a pro in there to find out what and where the trouble is.
1. Is this a ground fault outlet/switch? if so there is another breaker for it at the pole not just at the breaker box, many times they look fine but you need to press them
2. It sounds like you have a plug/s run by 2 switches. If this is right they are called 3 way switches (why not 2 way? who knows some guy named them <g>) 3 way switches cost more than standard switches make sure you are getting the right one. When you take it down take a picture or draw it (or both) because if you get the wires in wrong spot one switch works the other won't. (DH did not listen to me.)
I had a BC 10 amp light switch fitted to the safety board in my garage with 2 sets of fluro lights. I thought I was turning the switch on wrong! Initially it would make a buzzing noise and sometimes would turn lights on and other times it wouldn't. Electrician who fitted the switch and lights says its not his wiring, it's the lights.
The switch would initially set safety switch off and cut power in the garage, or lights would trip its own switch and turn off? I have spoken to Midis who say it's the switch not the lights! My thought is it is the switch or the way it has been fitted. Any ideas? I am not sure why a normal light switch wasn't wired at the time.I have this stairs' light circuit, but the LED won't turn off. What can I do?
The capacitor is there to debounce the switch.
When the button is pushed, the negative terminal of the op amp is at 0 volts. The positive terminal is at 2/3 of Vcc. This drives the output of the op amp high (to Vcc).
With the button released the positive terminal stays at 2/3 of Vcc. The negative terminal must rise above that value to drive the output low. Evidently the input impedance of the op amp is less than 2 M ohms so the negative is staying below 2/3 Vcc. (input impedance for an op amp is typically 1 to 2 M ohms). Assuming an input resistance greater than 1 M ohm, decreasing the 1 M ohm resistor to a 500 k ohm resistor would cause the input voltage of the negative input to rise above 2/3 Vcc and the output would shut off. Care must be taken because this will increase the current flow to he input of the op amp which could shorten its life.
I have a 3 switches for the lights and vent fan in my bathroom. The second and third switches work fine every time, but the first one does not turn the light on unless I play with it or I hit it.
Does this sound like a electrical issue that I need to be concerned with, especially when it comes to safety?Hire an electrician to change the switch. From what you have described, it is going bad.
We have a problem where a light in the stairwell is controlled by 2 - 3way switches, however not in the traditional sense. When you turn the light on with one switch, you have to turn it back off with the same switch. It can be either one, but it must be the same one to turn on and back off.
I've rewired the entire circuit. (I'm an industrial controls electrician.) With no power on the circuit, I checked the resistance through the switches. The circuit performs perfectly. When I apply power, we have the same issue.
I removed the light fixture and inserted the voltmeter between the power coming back from the switch to the fixture (hot). I tie the other lead of the meter to the neutral of the power coming in. Theoretically I should see 0 volts (or very close) when the switches are in one position, and then changing to 120 volts and back, but I don't. I see 120 volts and as I switch one or another switch it goes to 105 volts or 110 volts.
I'm not entirely sure what I have on my hands here. I have only 2 wires (old) power coming into the new circuit I've replaced, so there is no ground to check to. I'm thinking someone might have crossed the wires and I may be switching neutral?
I'm not sure. I guess I will be re-wiring the rest of the incoming circuit as well. :-(
One of the two switches has the power coming in with no ground. It would be good to run a ground.
This switch has the hot wire connected to it (or possibly the neutral if someone crossed the wires). The two wires coming off the switch on a three way will always have one wire hot and one not. These are the "travellers". You can use your meter to measure the voltage between a traveller and the neutral to make sure the switch is working correctly. The hot traveller will change with switch position.
The second switch should receive the two travellers from the first switch. The output wire from the second switch, called the switch leg, goes to the light. You can use your meter to make sure that one traveller is hot from the other switch, then throw the other switch and make sure the other traveller is hot.
The neutral should be continuous through all this and its voltage to any ground (water line, drain line, furnace duct) should be zero.
I just replaced a wall switch and it still won't work. The tester shows a dim light. This wall switch is connected to the ceiling fan. Please help.
I would call in an electrician.
You replaced a switch, presumably because it was not working, and the fan still doesn't work.
I assume this is the only switch for the fan.
Usually, and with good working practice, the hot wire is switched. But for the fan to work, both a hot and neutral are required.
An electrician would have a meter to test for continuity between the neutral and the ground at the fan, since they are connected in your panel.
The electrician would also check the inexpensive switch that is part of the fan. These often go bad. Is it possible the fan is turned off here?
Some fans have remote controls and it could be the fan is not in run mode.
Good Luck